Woodward raised the standard in genset paralleling control and power management system with the easYgen-3000XT Series controllers. These controllers come with standardized software that is simple to configure, yet easily customized for individual applications. Enhanced connectivity enables fast, reliable and secure interfac-ing to other controls and communications systems while the enhanced hardware is a drop-in replacement for previous generation easYgen-3000 Series Controls.
Targeted at enabling complex power management applications, the easYgen-3500XT supports easYgen | GC-3000XT to manage a large genset fleet of up to 496 sets and easYgen | LS-6XT to control up to 64 synchroniz-ing breaker or manual switches on up to 128 complex bus segments. Redundant load sharing is selectable us-ing Ethernet B and C networks for enhanced reliability. The control combines complete engine-generator con-trol and protection with advanced, peer-to-peer paralleling functionality and innovative features in a robust, at-tractive, user-friendly and all-in-one package. The easYgen-3500 XT controls are designed to direct connect up to 690Vac and operate to 4000m above sea level without derating.
The easYgen-3500XT is available in two packages. P1, focused at complex paralleling applications provides redundant Ethernet communication, LS-5 connectivity, and standard I/O set, while P2, Co-Gen/CHP model offers expanded onboard I/O set, 3-ph busbar voltage measurement capability and phase rotation monitoring between gen-busbar and busbar-utility. These packages are available without a display in a rugged metal hous-ing suitable for back panel installations (easYgen-3400XT-P1 and easYgen-3400XT-P2 respectively). A sophis-ticated touch screen remote panel (RP-3000XT) complements them as an operator control panel. A version of easYgen-3500XT (easYgen-3500XT-P1-LT and easYgen-3500XT-P2-LT) is designed to operate down to -400 C for outdoor applications.
Optionen
3100 XT Lite | 3100XT | 3400 XT-Paket 1 | 3400 XT-Paket 2 | |
---|---|---|---|---|
Synchronisation | ||||
Generator-Leistungsschalter | ||||
Netzschalter | ||||
Generator-Gruppenschalter | ||||
Anlauf / Schwarzstart | ||||
Schutz | ||||
Generator | ||||
Motor | ||||
Netz | ||||
Hardware | ||||
CANBus-Anschlüsse | 2 | 2 | 3 | 3 |
RS485 | ||||
Ethernet-Modbus-TCP-Ports | 1 | 1 | 3 | 3 |
Free configurable PID's (eg. speed & voltage bias) | 3 | 3 | 3 | 3 |
Sammelschienenerkennung, Netzerkennung | ||||
690 Vac Messung | ||||
Netzstrom Messung | ||||
Messung der Sammelschienenspannung | 2 Phasen | 2 Phasen | 3 Phasen | |
Digitale Eingänge | 12 | 12 | 12 | 23 |
Digitale Ausgänge | 12 | 12 | 12 | 22 |
Analoge Eingänge | 3 | 3 | 3 | 10 |
Analoge Ausgänge | 2 | 2 | 2 | 6 |
PWM-Ausgänge für kWh und kVArh | ||||
Funktionen | ||||
Lastverteilung über CAN und / oder Ethernet | ||||
Redundante Lastverteilung über Ethernet und / oder CANopen | ||||
unterstützt den Gruppen-Controller, LS-5 und LS-6XT | ||||
Lastabhängiger Start-Stopp | ||||
Import-Export-Regelung | ||||
PV (photovoltaic) control | ||||
AVR integral voltage regulation (with exciter-10) | *upgrade available | *upgrade available | ||
Funktionen für Mietanwendungen: vier umschaltbare Parametersätze, zusätzliche Zähler zur Abrechnung, … | ||||
Betriebstemperatur | -40 °C bis +70 °C | -40 °C bis +70 °C | -40 °C bis +70 °C | -40 °C bis +70 °C |
Artikelnummer | 8440-2280 | 8440-2081 | 8440-2084 | 8440-2087 |
Produktspezifikation | Produktspezifikation | Produktspezifikation |
3100 XT Paket 1 VERMIETUNG | 3400 XT Paket 1 VERMIETUNG | 3400 XT Paket 2 MIETE | |
---|---|---|---|
Synchronisation | |||
Generator-Leistungsschalter | |||
Netzschalter | |||
Generator-Gruppenschalter | |||
Anlauf / Schwarzstart | |||
Schutz | |||
Generator | |||
Motor | |||
Netz | |||
Hardware | |||
CANBus-Anschlüsse | 2 | 3 | 3 |
RS485 | |||
Ethernet-Modbus-TCP-Ports | 1 | 3 | 3 |
Free configurable PID's (eg. speed & voltage bias) | 3 | 3 | 3 |
Sammelschienenerkennung, Netzerkennung | |||
690 Vac Messung | |||
Netzstrom Messung | |||
Messung der Sammelschienenspannung | 2 Phasen | 2 Phasen | 3 Phasen |
Digitale Eingänge | 12 | 12 | 23 |
Digitale Ausgänge | 12 | 12 | 22 |
Analoge Eingänge | 3 | 3 | 10 |
Analoge Ausgänge | 2 | 2 | 6 |
PWM-Ausgänge für kWh und kVArh | |||
Funktionen | |||
Lastverteilung über CAN und / oder Ethernet | |||
Redundante Lastverteilung über Ethernet und / oder CANopen | |||
unterstützt den Gruppen-Controller, LS-5 und LS-6XT | |||
Lastabhängiger Start-Stopp | |||
Import-Export-Regelung | |||
PV (photovoltaic) control | |||
AVR integral voltage regulation (with exciter-10) | *upgrade available | ||
Funktionen für Mietanwendungen: vier umschaltbare Parametersätze, zusätzliche Zähler zur Abrechnung, … | |||
Betriebstemperatur | -40 °C bis +70 °C | -40 °C bis +70 °C | -40 °C bis +70 °C |
Artikelnummer | 8440-2284 | 8440-2287 | 8440-2289 |
Optionen
3200 XT Lite | 3200XT | 3500 XT-Paket 1 | 3500 XT-Paket 2 | |
---|---|---|---|---|
Synchronisation | ||||
Generator-Leistungsschalter | ||||
Netzschalter | ||||
Generator-Gruppenschalter | ||||
Anlauf / Schwarzstart | ||||
Schutz | ||||
Generator | ||||
Motor | ||||
Netz | ||||
Hardware | ||||
CANBus-Anschlüsse | 2 | 2 | 3 | 3 |
RS485 | ||||
Ethernet-Modbus-TCP-Ports | 1 | 1 | 3 | 3 |
Free configurable PID's (eg. speed & voltage bias) | 3 | 3 | 3 | 3 |
Sammelschienenerkennung, Netzerkennung | ||||
690 Vac Messung | ||||
Netzstrom Messung | ||||
Messung der Sammelschienenspannung | 2 Phasen | 2 Phasen | 3 Phasen | |
Digitale Eingänge | 12 | 12 | 12 | 23 |
Digitale Ausgänge | 12 | 12 | 12 | 22 |
Analoge Eingänge | 3 | 3 | 3 | 10 |
Analoge Ausgänge | 2 | 2 | 2 | 6 |
PWM-Ausgänge für kWh und kVArh | ||||
Funktionen | ||||
Lastverteilung über CAN und / oder Ethernet | ||||
Redundante Lastverteilung über Ethernet und / oder CANopen | ||||
unterstützt den Gruppen-Controller, LS-5 und LS-6XT | ||||
Lastabhängiger Start-Stopp | ||||
Import-Export-Regelung | ||||
PV (photovoltaic) control | ||||
AVR integral voltage regulation (with exciter-10) | *upgrade available | *upgrade available | ||
Funktionen für Mietanwendungen: vier umschaltbare Parametersätze, zusätzliche Zähler zur Abrechnung, … | ||||
Betriebstemperatur | -20 °C bis 70 °C | -20 °C bis 70 °C | -20 °C bis 70 °C | -20 °C bis 70 °C |
Artikelnummer | 8440-2281 | 8440-2082 | 8440-2085 | 8440-2088 |
Produktspezifikation | Produktspezifikation | Produktspezifikation |
3200 XT LT-Lite | 3200 XT LT | 3500 XT Paket 1 LT | 3500 XT Paket 2 LT | |
---|---|---|---|---|
Synchronisation | ||||
Generator-Leistungsschalter | ||||
Netzschalter | ||||
Generator-Gruppenschalter | ||||
Anlauf / Schwarzstart | ||||
Schutz | ||||
Generator | ||||
Motor | ||||
Netz | ||||
Hardware | ||||
CANBus-Anschlüsse | 2 | 2 | 3 | 3 |
RS485 | ||||
Ethernet-Modbus-TCP-Ports | 1 | 1 | 3 | 3 |
Free configurable PID's (eg. speed & voltage bias) | 3 | 3 | 3 | 3 |
Sammelschienenerkennung, Netzerkennung | ||||
690 Vac Messung | ||||
Netzstrom Messung | ||||
Messung der Sammelschienenspannung | 2 Phasen | 2 Phasen | 3 Phasen | |
Digitale Eingänge | 12 | 12 | 12 | 23 |
Digitale Ausgänge | 12 | 12 | 12 | 22 |
Analoge Eingänge | 3 | 3 | 3 | 10 |
Analoge Ausgänge | 2 | 2 | 2 | 6 |
PWM-Ausgänge für kWh und kVArh | ||||
Funktionen | ||||
Lastverteilung über CAN und / oder Ethernet | ||||
Redundante Lastverteilung über Ethernet und / oder CANopen | ||||
unterstützt den Gruppen-Controller, LS-5 und LS-6XT | ||||
Lastabhängiger Start-Stopp | ||||
Import-Export-Regelung | ||||
PV (photovoltaic) control | ||||
AVR integral voltage regulation (with exciter-10) | *upgrade available | *upgrade available | ||
Funktionen für Mietanwendungen: vier umschaltbare Parametersätze, zusätzliche Zähler zur Abrechnung, … | ||||
Betriebstemperatur | -40 °C bis +70 °C | -40 °C bis +70 °C | -40 °C bis +70 °C | -40 °C bis +70 °C |
Artikelnummer | 8440-2272 | 8440-2083 | 8440-2086 | 8440-2089 |
Produktspezifikation | Produktspezifikation | Produktspezifikation |
3200 XT Paket 1 MIETE | 3500 XT Paket 1 VERMIETUNG | 3500XT Paket 2 VERMIETUNG | |
---|---|---|---|
Synchronisation | |||
Generator-Leistungsschalter | |||
Netzschalter | |||
Generator-Gruppenschalter | |||
Anlauf / Schwarzstart | |||
Schutz | |||
Generator | |||
Motor | |||
Netz | |||
Hardware | |||
CANBus-Anschlüsse | 2 | 3 | 3 |
RS485 | |||
Ethernet-Modbus-TCP-Ports | 1 | 3 | 3 |
Free configurable PID's (eg. speed & voltage bias) | 3 | 3 | 3 |
Sammelschienenerkennung, Netzerkennung | |||
690 Vac Messung | |||
Netzstrom Messung | |||
Messung der Sammelschienenspannung | 2 Phasen | 2 Phasen | 3 Phasen |
Digitale Eingänge | 12 | 12 | 23 |
Digitale Ausgänge | 12 | 12 | 22 |
Analoge Eingänge | 3 | 3 | 10 |
Analoge Ausgänge | 2 | 2 | 6 |
PWM-Ausgänge für kWh und kVArh | |||
Funktionen | |||
Lastverteilung über CAN und / oder Ethernet | |||
Redundante Lastverteilung über Ethernet und / oder CANopen | |||
unterstützt den Gruppen-Controller, LS-5 und LS-6XT | |||
Lastabhängiger Start-Stopp | |||
Import-Export-Regelung | |||
PV (photovoltaic) control | |||
AVR integral voltage regulation (with exciter-10) | *upgrade available | ||
Funktionen für Mietanwendungen: vier umschaltbare Parametersätze, zusätzliche Zähler zur Abrechnung, … | |||
Betriebstemperatur | -20 °C bis 70 °C | -20 °C bis 70 °C | -20 °C bis 70 °C |
Artikelnummer | 8440-2285 | 8440-2283 | 8440-2290 |
3200XT Paket 1 LT VERMIETUNG | 3500 XT Paket 1 LT MIETE | 3500XT Paket 2 LT VERMIETUNG | |
---|---|---|---|
Synchronisation | |||
Generator-Leistungsschalter | |||
Netzschalter | |||
Generator-Gruppenschalter | |||
Anlauf / Schwarzstart | |||
Schutz | |||
Generator | |||
Motor | |||
Netz | |||
Hardware | |||
CANBus-Anschlüsse | 2 | 3 | 3 |
RS485 | |||
Ethernet-Modbus-TCP-Ports | 1 | 3 | 3 |
Free configurable PID's (eg. speed & voltage bias) | 3 | 3 | 3 |
Sammelschienenerkennung, Netzerkennung | |||
690 Vac Messung | |||
Netzstrom Messung | |||
Messung der Sammelschienenspannung | 2 Phasen | 2 Phasen | 3 Phasen |
Digitale Eingänge | 12 | 12 | 23 |
Digitale Ausgänge | 12 | 12 | 22 |
Analoge Eingänge | 3 | 3 | 10 |
Analoge Ausgänge | 2 | 2 | 6 |
PWM-Ausgänge für kWh und kVArh | |||
Funktionen | |||
Lastverteilung über CAN und / oder Ethernet | |||
Redundante Lastverteilung über Ethernet und / oder CANopen | |||
unterstützt den Gruppen-Controller, LS-5 und LS-6XT | |||
Lastabhängiger Start-Stopp | |||
Import-Export-Regelung | |||
PV (photovoltaic) control | |||
AVR integral voltage regulation (with exciter-10) | *upgrade available | ||
Funktionen für Mietanwendungen: vier umschaltbare Parametersätze, zusätzliche Zähler zur Abrechnung, … | |||
Betriebstemperatur | -40 °C bis +70 °C | -40 °C bis +70 °C | -40 °C bis +70 °C |
Artikelnummer | 8440-2286 | 8440-2288 | 8440-2291 |