![MFR300 MFR300](https://easygen.org/wp-content/uploads/2022/03/MFR300_1500x950-300x190-1.png)
Merjenje in zaščita
Merilni pretvornik in zaščitna naprava za enofazne in trifazne električne sisteme.
-
- priključite PLC prek vodila CAN
- uporabite releje za potiskanje ukazov in za nadzor odklopnika
Merjenje
Easyprotec 1410 | MFR300 | |
---|---|---|
Funkcije | ||
3 resnični RMS napetostni vhodi | ||
3 pravi RMS tokovni vhodi | ||
Merilna natančnost razreda 0,5 | ||
Nastavljive nastavitvene vrednosti izklopa/kontrole | ||
Nastavljivi časovniki zakasnitve za posamezni alarmi (0,02 do 300,00 s) | ||
4 nastavljivi releji (preklop) | 2 | 4 |
1 Rele "Pripravljen za delovanje". | ||
Preklopna relejna logika | ||
2 kWh števca (maks. 1012 kWh) | ||
2 kvarh števca (maks. 1012 kvarh) | ||
Komunikacija CANopen / Modbus | ||
Nastavljivo preko CAN vodila / RS-485 / Servisna vrata (USB/RS-232) | ||
Nastavljivo prek servisnih vrat (USB / RS-232) | ||
Zaščita | ||
Previsoka/prenizka napetost (59/27) | ||
Previsoka/nizka frekvenca (81O/U) | ||
Asimetrija napetosti (47) | ||
Preobremenitev (32) | ||
Pozitivna/negativna obremenitev (32R/F) | ||
Neuravnotežena obremenitev (46) | ||
Fazni premik (78) | ||
Prekomerni tok (50/51) | ||
df/dt (ROCOF) | ||
Ozemljitvena napaka | ||
QV spremljanje | ||
Povečanje napetosti | ||
Prosto nastavljivo časovno odvisno spremljanje podnapetosti za: FRT (prehod po napaki) |
MFR-300 Multifunction Relay / Measuring Transducer with CANopen / Modbus Communication
The MFR 300 is a measuring transducer for monitoring single- and three-phase power systems. The MFR 300 has both voltage and current inputs for measuring an electrical power source. A digital processor makes it possible to accurately to measure true RMS values, regardless of harmonics, transients or disturbing pulses. The primary measured and calculated values are transmitted via CANopen / Modbus protocol to a supervisory control system.
The MFR 300 performs monitoring functions for mains decoupling, including four freely configurable time-dependent undervoltage monitoring functions for FRT (fault ride-through).
The primary measured values of voltage and current are used to calculate the real, reactive, and apparent power and the power factor (cosphi) values.
Dodatki
![Konfiguracijska programska oprema Configuration Software](https://easygen.org/wp-content/uploads/2022/03/accessories4.webp)
Zbirka orodij
configuration via Woodward’s standard Software Toolkit.
![usb kabel USB](https://easygen.org/wp-content/uploads/2022/03/usbCable.webp)
USB konfiguracijski vmesnik
Vmesnik za konfiguracijo vrat USB. Stran osebnega/prenosnega računalnika je ločena od strani enote Woodward z galvansko izolacijo.
številka dela: 5417-1251