genset control
easYgen3000XT
Woodward raised the standard in genset paralleling control and power management system with the easYgen-3000XT Series controllers. These controllers come with standardized software that is simple to configure, yet easily customized for individual applications. Enhanced connectivity enables fast, reliable and secure interfac-ing to other controls and communications systems while the enhanced hardware is a drop-in replacement for previous generation easYgen-3000 Series Controls.
Targeted at enabling complex power management applications, the easYgen-3500XT supports easYgen | GC-3000XT to manage a large genset fleet of up to 496 sets and easYgen | LS-6XT to control up to 64 synchroniz-ing breaker or manual switches on up to 128 complex bus segments. Redundant load sharing is selectable us-ing Ethernet B and C networks for enhanced reliability. The control combines complete engine-generator con-trol and protection with advanced, peer-to-peer paralleling functionality and innovative features in a robust, at-tractive, user-friendly and all-in-one package. The easYgen-3500 XT controls are designed to direct connect up to 690Vac and operate to 4000m above sea level without derating.
The easYgen-3500XT is available in two packages. P1, focused at complex paralleling applications provides redundant Ethernet communication, LS-5 connectivity, and standard I/O set, while P2, Co-Gen/CHP model offers expanded onboard I/O set, 3-ph busbar voltage measurement capability and phase rotation monitoring between gen-busbar and busbar-utility. These packages are available without a display in a rugged metal hous-ing suitable for back panel installations (easYgen-3400XT-P1 and easYgen-3400XT-P2 respectively). A sophis-ticated touch screen remote panel (RP-3000XT) complements them as an operator control panel. A version of easYgen-3500XT (easYgen-3500XT-P1-LT and easYgen-3500XT-P2-LT) is designed to operate down to -400 C for outdoor applications.
Options
3100 XT Lite | 3100 XT | 3400 XT Package 1 | 3400 XT Package 2 | |
---|---|---|---|---|
Synchronization | ||||
generator circuit breaker | ||||
mains circuit breaker | ||||
generator group breaker | ||||
Run Up / Black Start | ||||
Protection | ||||
generator | ||||
engine | ||||
mains | ||||
Hardware | ||||
CANBus ports | 2 | 2 | 3 | 3 |
RS485 | ||||
Ethernet Modbus TCP ports | 1 | 1 | 3 | 3 |
Free configurable PID's (eg. speed & voltage bias) | 3 | 3 | 3 | 3 |
busbar sensing, mains sensing | ||||
690 VAC sensing | ||||
mains current sensing | ||||
Busbar voltage sensing | 2 phase | 2 phase | 3 phase | |
Digital Inputs | 12 | 12 | 12 | 23 |
Digital Outputs | 12 | 12 | 12 | 22 |
Analog Inputs | 3 | 3 | 3 | 10 |
Analog Outputs | 2 | 2 | 2 | 6 |
PWM outputs for kWh and kVArh | ||||
Functions | ||||
load sharing via CAN and / or Ethernet | ||||
redundant load sharing via Ethernet and / or CANopen | ||||
support group controller LS-5 and LS-6XT | ||||
load dependent start-stop | ||||
import-export control | ||||
PV (photovoltaic) control | ||||
AVR integral voltage regulation (with exciter-10) | *upgrade available | *upgrade available | ||
rental functions: four switchable parameter sets, additional counters for billing, … | ||||
operating temperature | -40°C to +70°C | -40°C to +70°C | -40°C to +70°C | -40°C to +70°C |
Part number | 8440-2280 | 8440-2081 | 8440-2084 | 8440-2087 |
product specification | product specification | product specification |
3100 XT Package 1 RENTAL | 3400 XT Package 1 RENTAL | 3400 XT Package 2 RENTAL | |
---|---|---|---|
Synchronization | |||
generator circuit breaker | |||
mains circuit breaker | |||
generator group breaker | |||
Run Up / Black Start | |||
Protection | |||
generator | |||
engine | |||
mains | |||
Hardware | |||
CANBus ports | 2 | 3 | 3 |
RS485 | |||
Ethernet Modbus TCP ports | 1 | 3 | 3 |
Free configurable PID's (eg. speed & voltage bias) | 3 | 3 | 3 |
busbar sensing, mains sensing | |||
690 VAC sensing | |||
mains current sensing | |||
Busbar voltage sensing | 2 phase | 2 phase | 3 phase |
Digital Inputs | 12 | 12 | 23 |
Digital Outputs | 12 | 12 | 22 |
Analog Inputs | 3 | 3 | 10 |
Analog Outputs | 2 | 2 | 6 |
PWM outputs for kWh and kVArh | |||
Functions | |||
load sharing via CAN and / or Ethernet | |||
redundant load sharing via Ethernet and / or CANopen | |||
support group controller LS-5 and LS-6XT | |||
load dependent start-stop | |||
import-export control | |||
PV (photovoltaic) control | |||
AVR integral voltage regulation (with exciter-10) | *upgrade available | ||
rental functions: four switchable parameter sets, additional counters for billing, … | |||
operating temperature | -40°C to +70°C | -40°C to +70°C | -40°C to +70°C |
Part number | 8440-2284 | 8440-2287 | 8440-2289 |
Options
3200 XT Lite | 3200 XT | 3500 XT Package 1 | 3500 XT Package 2 | |
---|---|---|---|---|
Synchronization | ||||
generator circuit breaker | ||||
mains circuit breaker | ||||
generator group breaker | ||||
Run Up / Black Start | ||||
Protection | ||||
generator | ||||
engine | ||||
mains | ||||
Hardware | ||||
CANBus ports | 2 | 2 | 3 | 3 |
RS485 | ||||
Ethernet Modbus TCP ports | 1 | 1 | 3 | 3 |
Free configurable PID's (eg. speed & voltage bias) | 3 | 3 | 3 | 3 |
busbar sensing, mains sensing | ||||
690 VAC sensing | ||||
mains current sensing | ||||
Busbar voltage sensing | 2 phase | 2 phase | 3 phase | |
Digital Inputs | 12 | 12 | 12 | 23 |
Digital Outputs | 12 | 12 | 12 | 22 |
Analog Inputs | 3 | 3 | 3 | 10 |
Analog Outputs | 2 | 2 | 2 | 6 |
PWM outputs for kWh and kVArh | ||||
Functions | ||||
load sharing via CAN and / or Ethernet | ||||
redundant load sharing via Ethernet and / or CANopen | ||||
support group controller LS-5 and LS-6XT | ||||
load dependent start-stop | ||||
import-export control | ||||
PV (photovoltaic) control | ||||
AVR integral voltage regulation (with exciter-10) | *upgrade available | *upgrade available | ||
rental functions: four switchable parameter sets, additional counters for billing, … | ||||
operating temperature | -20 °C to 70 °C | -20 °C to 70 °C | -20 °C to 70 °C | -20 °C to 70 °C |
Part number | 8440-2281 | 8440-2082 | 8440-2085 | 8440-2088 |
product specification | product specification | product specification |
3200 XT LT Lite | 3200 XT LT | 3500 XT Package 1 LT | 3500 XT Package 2 LT | |
---|---|---|---|---|
Synchronization | ||||
generator circuit breaker | ||||
mains circuit breaker | ||||
generator group breaker | ||||
Run Up / Black Start | ||||
Protection | ||||
generator | ||||
engine | ||||
mains | ||||
Hardware | ||||
CANBus ports | 2 | 2 | 3 | 3 |
RS485 | ||||
Ethernet Modbus TCP ports | 1 | 1 | 3 | 3 |
Free configurable PID's (eg. speed & voltage bias) | 3 | 3 | 3 | 3 |
busbar sensing, mains sensing | ||||
690 VAC sensing | ||||
mains current sensing | ||||
Busbar voltage sensing | 2 phase | 2 phase | 3 phase | |
Digital Inputs | 12 | 12 | 12 | 23 |
Digital Outputs | 12 | 12 | 12 | 22 |
Analog Inputs | 3 | 3 | 3 | 10 |
Analog Outputs | 2 | 2 | 2 | 6 |
PWM outputs for kWh and kVArh | ||||
Functions | ||||
load sharing via CAN and / or Ethernet | ||||
redundant load sharing via Ethernet and / or CANopen | ||||
support group controller LS-5 and LS-6XT | ||||
load dependent start-stop | ||||
import-export control | ||||
PV (photovoltaic) control | ||||
AVR integral voltage regulation (with exciter-10) | *upgrade available | *upgrade available | ||
rental functions: four switchable parameter sets, additional counters for billing, … | ||||
operating temperature | -40°C to +70°C | -40°C to +70°C | -40°C to +70°C | -40°C to +70°C |
Part number | 8440-2272 | 8440-2083 | 8440-2086 | 8440-2089 |
product specification | product specification | product specification |
3200 XT Package 1 RENTAL | 3500 XT Package 1 RENTAL | 3500XT Package 2 RENTAL | |
---|---|---|---|
Synchronization | |||
generator circuit breaker | |||
mains circuit breaker | |||
generator group breaker | |||
Run Up / Black Start | |||
Protection | |||
generator | |||
engine | |||
mains | |||
Hardware | |||
CANBus ports | 2 | 3 | 3 |
RS485 | |||
Ethernet Modbus TCP ports | 1 | 3 | 3 |
Free configurable PID's (eg. speed & voltage bias) | 3 | 3 | 3 |
busbar sensing, mains sensing | |||
690 VAC sensing | |||
mains current sensing | |||
Busbar voltage sensing | 2 phase | 2 phase | 3 phase |
Digital Inputs | 12 | 12 | 23 |
Digital Outputs | 12 | 12 | 22 |
Analog Inputs | 3 | 3 | 10 |
Analog Outputs | 2 | 2 | 6 |
PWM outputs for kWh and kVArh | |||
Functions | |||
load sharing via CAN and / or Ethernet | |||
redundant load sharing via Ethernet and / or CANopen | |||
support group controller LS-5 and LS-6XT | |||
load dependent start-stop | |||
import-export control | |||
PV (photovoltaic) control | |||
AVR integral voltage regulation (with exciter-10) | *upgrade available | ||
rental functions: four switchable parameter sets, additional counters for billing, … | |||
operating temperature | -20 °C to 70 °C | -20 °C to 70 °C | -20 °C to 70 °C |
Part number | 8440-2285 | 8440-2283 | 8440-2290 |
3200XT Package 1 LT RENTAL | 3500 XT Package 1 LT RENTAL | 3500XT Package 2 LT RENTAL | |
---|---|---|---|
Synchronization | |||
generator circuit breaker | |||
mains circuit breaker | |||
generator group breaker | |||
Run Up / Black Start | |||
Protection | |||
generator | |||
engine | |||
mains | |||
Hardware | |||
CANBus ports | 2 | 3 | 3 |
RS485 | |||
Ethernet Modbus TCP ports | 1 | 3 | 3 |
Free configurable PID's (eg. speed & voltage bias) | 3 | 3 | 3 |
busbar sensing, mains sensing | |||
690 VAC sensing | |||
mains current sensing | |||
Busbar voltage sensing | 2 phase | 2 phase | 3 phase |
Digital Inputs | 12 | 12 | 23 |
Digital Outputs | 12 | 12 | 22 |
Analog Inputs | 3 | 3 | 10 |
Analog Outputs | 2 | 2 | 6 |
PWM outputs for kWh and kVArh | |||
Functions | |||
load sharing via CAN and / or Ethernet | |||
redundant load sharing via Ethernet and / or CANopen | |||
support group controller LS-5 and LS-6XT | |||
load dependent start-stop | |||
import-export control | |||
PV (photovoltaic) control | |||
AVR integral voltage regulation (with exciter-10) | *upgrade available | ||
rental functions: four switchable parameter sets, additional counters for billing, … | |||
operating temperature | -40°C to +70°C | -40°C to +70°C | -40°C to +70°C |
Part number | 8440-2286 | 8440-2288 | 8440-2291 |