Auto Start Stop and Automatic Mains Failure
- Reduced effort through product standardization for optimized inventory, manufacturing, commissioning and service
- Enhanced communication with built-in Ethernet, CAN (J1939), RS-485 (Modbus), RS232 (Modem), USB (Service) interfaces
- Heavy duty relays for engine, breaker and application interface
- Life time event logging for detailed troubleshooting and root cause analysis
- Best in class LCD display for enhanced user experience
- Multi-lingual customizable on site, there are 2 standard languages plus 1 free slot for your custom language
- Comprehensive engine, generator and utility protection
Start/Stop | Start/Stop | Start/Stop | |
---|---|---|---|
easYgen-400 | easYgen-600 | easYgen-800 | |
Display | Monochrome | Monochrome | TFT LCD |
resolution | (132 x 64) | (132 x 64) | 4.3” (480 x 272) |
Digital Inputs | 3 | 5 | 8 |
Digital Outputs | 6 | 6 | 8 |
Analog Inputs | 4 | 3 | 5 |
Interfaces: | |||
CANJ1939 | |||
USB | |||
RS-485 | |||
SD-Card Slot | |||
Ethernet | |||
Power Supply: 8-35VDC | |||
Operating Temp: -25 ... +70°C | |||
Measuring | |||
Generator voltage (3-phase/4-wire) | |||
Generator current (3x TrueRMS) | |||
Mains voltage (3-phase/4-wire) | |||
Earth current (1x TrueRMS) | |||
Control | |||
Mains supply monitoring and automatic changeover | |||
GCB and MCB control | GCB | GCB | GCB |
Start/stop sequence for diesel and gas engines | Diesel | Diesel | Diesel/Gas |
Isolated single unit operation | |||
AMF (Automatic Mains Failure operation) | |||
Stand-by operation | |||
Open transition (break-before-make) | |||
ATS (Automatic Transfer Switching) | |||
Remote monitoring and control (modem support) | |||
Protection | |||
Generator: voltage | |||
Generator: frequency | |||
Generator: loss of phase | |||
Generator: phase sequency | |||
Generator: current | |||
Generator: reverse power | |||
Generator: overload | |||
Generator: earth fault | |||
Mains: voltage | |||
Mains: frequency | |||
Mains: loss of phase | |||
Mains: phase sequency | |||
Engine: over speed | |||
Engine: under speed | |||
Engine: loss of speed | |||
Engine: crank disconnect | |||
Battery voltage | |||
Display customizable power-up text and image | |||
Display configuration with PIN protection | |||
Counters: operating hours/start/maintenance | |||
kWh, kvarh | |||
Real Time Clock | |||
Event recorder | 50 | 50 | 99 (+SD card slot) |
Switchable parameter set | |||
Magnetic Pickup | |||
environmental protection: IP65 | |||
compliance: CE, UL/cUL | |||
Panel Cut-Out | 116 x 90 | 186 x 141 | 214 x 160 |
8440-2250 | 8440-2252 | 8440-2254 |
AMF | AMF | AMF | AMF | |
---|---|---|---|---|
easYgen-1400 | easYgen-1600 | easYgen-1700 | easYgen-1800 | |
Display | Monochrome | Monochrome | Monochrome | TFT LCD |
resolution | (132 x 64) | (132 x 64) | (240 x 128) | 4.3” (480 x 272) |
Digital Inputs | 3 | 5 | 8 | 8 |
Digital Outputs | 6 | 6 | 8 | 8 |
Analog Inputs | 4 | 3 | 5 | 5 |
Interfaces: | ||||
CANJ1939 | ||||
USB | ||||
RS-485 | ||||
SD-Card Slot | ||||
Ethernet | ||||
Power Supply: 8-35VDC | ||||
Operating Temp: -25 ... +70°C | ||||
Measuring | ||||
Generator voltage (3-phase/4-wire) | ||||
Generator current (3x TrueRMS) | ||||
Mains voltage (3-phase/4-wire) | ||||
Earth current (1x TrueRMS) | ||||
Control | ||||
Mains supply monitoring and automatic changeover | ||||
GCB and MCB control | GCB/MCB | GCB/MCB | GCB/MCB | GCB/MCB |
Start/stop sequence for diesel and gas engines | Diesel | Diesel | Diesel/Gas | Diesel/Gas |
Isolated single unit operation | ||||
AMF (Automatic Mains Failure operation) | ||||
Stand-by operation | ||||
Open transition (break-before-make) | ||||
ATS (Automatic Transfer Switching) | ||||
Remote monitoring and control (modem support) | ||||
Protection | ||||
Generator: voltage | ||||
Generator: frequency | ||||
Generator: loss of phase | ||||
Generator: phase sequency | ||||
Generator: current | ||||
Generator: reverse power | ||||
Generator: overload | ||||
Generator: earth fault | ||||
Mains: voltage | ||||
Mains: frequency | ||||
Mains: loss of phase | ||||
Mains: phase sequency | ||||
Engine: over speed | ||||
Engine: under speed | ||||
Engine: loss of speed | ||||
Engine: crank disconnect | ||||
Battery voltage | ||||
Display customizable power-up text and image | ||||
Display configuration with PIN protection | ||||
Counters: operating hours/start/maintenance | ||||
kWh, kvarh | ||||
Real Time Clock | ||||
Event recorder | 50 | 50 | 99 | 99 (+SD card slot) |
Switchable parameter set | ||||
Magnetic Pickup | ||||
environmental protection: IP65 | ||||
compliance: CE, UL/cUL | ||||
Panel Cut-Out | 116 x 90 | 186 x 141 | 214 x 160 | 214 x 160 |
8440-2251 | 8440-2253 | 8440-2256 | 8440-2255 |
Accessories

ToolKit SC
The easYgen 100 and 1000 Series require the “ToolKit SC” (different than the “ToolKit” for the easYgen3000 Series)

Annunciator – easYlite 200
-
- for easYgen-100/1000 Series
- 16 freely configurable LEDs
- CAN bus interface
- RS-485 interface
- Self check features

Digital I/O Expansion Board
-
- 8 discrete inputs
- 8 relay outputs
- CAN bus communication

Spare connectors
-
- Spare Connector KIT EG-400/1400: 10-009-352
- Spare Connector KIT EG-600/1600: 10-004-674
- Spare Connector KIT EG-800/1700/1800: 10-004-675